Specification
Size | 1/4” | 1/2” |
---|---|---|
Orifice Size | 4.3 | 6.5 |
CV Value | 0.1 | 0.3 |
Max Working Pressure | 206bar | |
Max. Working Temperature |
-10~80°C (14~176°F) | |
Actuator Pressure Rating | 5~7bar(73~101psig) | |
Internal leakage Allowance-He |
≤1x10-9 atm.cc/s | |
External leakage Allowance-He |
≤1x10-9 atm.cc/s |
Ordering Information & Dimensions

Part Number | End Connection | Dimensions (mm) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | L | H | h1 | h2 | W | E | F | K | |||
VCDS | C-04M- | 1/4“ Male UCR | 58.4 | 110.6 | 11.1 | 71.7 | 48.0 | 25.4 | 26.0 | M5 | ||
C-04F- | 1/4“ Female UCR | 70.6 | ||||||||||
C-08M- | 1/2” Male UCR | 73.6 | 121.4 | 16.0 | 70.6 | 62.0 | 28.0 | 37.0 | ||||
C-08F- | 1/2” Female UCR | 83.0 |
- In CLOSE state, You can lock the handle by lifting the handle.
- When turning the handle to the OPEN state, be sure to turn the handle down.
- When you fasten the lock with the handle raised, you can prevent the handle from going down.
- The lock can be fastened only with the handle lifted up in CLOSE state.